SungjuNewPrime/OPC Server Setting/OPC서버 관련자료 - TEST/DxpServer7/DxpServer_v7201/Readme_J.html
2026-09-04 11:15:47 +09:00

816 lines
46 KiB
HTML
Raw Permalink Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=shift_jis">
<meta http-equiv="Content-Language" content="ja">
<title>デバイスエクスプローラ OPCサーバー ReadMe</title>
<style type="text/css">
<!--
body { font-size: 12pt; }
a:visited { color: royalblue; }
a:hover { color: blue; background-color: lightblue; }
h2 { color: black; background-color: "#4169E1"; }
h3 { color: #000080; background-color: "#C8DDFF"; }
fieldset { font-size: 9pt; }
table.ReleaseNote
{
border: 1px solid silver;
padding: 1px;
border-spacing: 0px;
}
table.ReleaseNote tr.Header
{
background-color: silver;
}
table.ReleaseNote td
{
font-size: 10pt;
border: 1px solid silver;
padding: 1px;
border-spacing: 0px;
text-align: left
vertical-align: middle;
}
-->
</style>
</head>
<body>
<a name="_top">
<hr size="2" color="#4169E1">
<table width="100%" border="0" cellpadding="0" cellspacing="0">
<tr>
<td width="100%" height="80" bgcolor="#C8DDFF" align="center">
<b><font size=4 color="#000080">デバイスエクスプローラ OPCサーバー<br>Version 7.2.0 ReadMe</font></b>
</td>
</tr>
</table>
<hr size="2" color="#4169E1">
<div align="right">2023年8月</div>
<br>
<br>
<ol>
<li><a target="_self" href="#Disk" >データ</a>
<li><a target="_self" href="#Release" >リリースノート</a>
<ul type="disc">
<font size="2">
<li><a target="_self" href="#Release7.2.0">Ver 7.2.0</a>
<li><a target="_self" href="#Release7.1.1">Ver 7.1.1</a>
<li><a target="_self" href="#Release7.1.0">Ver 7.1.0</a>
<li><a target="_self" href="#Release7.0.1">Ver 7.0.1</a>
<li><a target="_self" href="#Release7.0.0">Ver 7.0.0</a>
</font>
</ol>
</ol>
<br>
<a name="Disk"><hr></a>
<h2> 1.  データ</h2>
<blockquote>
この データ に収納されているソフトウェアは、次の通りです。<br>
<table border="1" bordercolor="white" cellpadding=15>
<tr>
<td bordercolor="gray">
<pre style="font-size: 9pt;">
\-+-Readme_J.html ・・・・・・・・・・・ 本ファイル
|
+-Setup.exe ・・・・・・・・・・・・・・・ インストーラ起動ファイル
|
+-OpcServer----+- ・・・・・・・・・ デバイスエクスプローラ OPCサーバー 32ビット版 セットアップファイル
| |
| +-EzSocketComponent ・・ MELSEC EZSocket コンポーネントセットアップファイル (※1)
| |
| +-EZCnctEnv ・・・・・・・・・・ MELSEC EZSocket 環境セットアップファイル (※1)
| |
| +-EZSocketNc ・・・・・・・・・ 三菱 CNC EZSocketNc コンポーネントセットアップファイル (※1)
|
+-OpcServer_x64 ・・・・・・・・・・・ デバイスエクスプローラ OPCサーバー 64ビット版 セットアップファイル
|
+-OpcClient ・・・・・・・・・・・・・・・ OPC DA クライアント環境セットアップファイル
|
+-Option ・・・・・・・・・・・・・・・・・・ オプションファイル
| |
| +-SWkeyOfflineActivation ・・・・・・・・ ライセンス要求ファイル作成用のテンプレートファイル (※2)
|
+-Doc----------+-JPN ・・・・・・ ユーザーズガイド、ソフトウェア使用権許諾契約書(日本語)
|
+-ENG ・・・・・・ ユーザーズガイド、ソフトウェア使用権許諾契約書(英語)
</pre>
</td>
</tr>
</table>
<fieldset>
<legend>注釈</legend>
※1 これらのコンポーネントは単独ではセットアップできません。<br>
<br>
※2 オフライン環境でソフトウェアキーを有効化する際に利用します。<br>
</fieldset>
</blockquote>
<div align="right"><a href="#_top" target="_self">先頭に戻る</a></div>
<a name="Release"><hr></a>
<h2> 2. リリースノート</h2>
<blockquote>
新機能追加、仕様変更、不具合修正の履歴<br>
<br>
<!---------------------------------------------------------------------------------------------------------------------------------------------->
<hr>
<a name="Release7.2.0"></a>
<h3>- Ver 7.2.0 - 2023年8月</h3>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 新機能</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目            </td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270301</td>
<td>全種</td>
<td>スクリプト機能においてMQTTでサブスクライブする機能に対応</td>
</tr>
</table>
</blockquote>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 仕様改善</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目            </td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270311</td>
<td>全種</td>
<td>シングルエディションにおいてライセンス認証の際に選択できる機種の制限を撤廃</td>
</tr>
<tr>
<td>1270312</td>
<td>全種</td>
<td>設定ツールがランタイムと接続する際に、設定内容の比較し、同じ設定であれば設定の読み出し書き込みの確認ポップアップを省略するように仕様変更</td>
</tr>
<tr>
<td>1270313</td>
<td>全種</td>
<td>共通プロパティの「起動時にランタイムと接続する」を「常にランタイムと接続する」に変更し、設定が有効な場合に意図せずランタイムと設定ツールが断線すると再接続するように仕様変更</td>
</tr>
<tr>
<td>1270321</td>
<td>FANUC Focas</td>
<td>プログラム名称の取得機能に対応</td>
</tr>
<tr>
<td>1270322</td>
<td>FANUC Focas</td>
<td>工具オフセットの一括読出機能に対応</td>
</tr>
<tr>
<td>1270323</td>
<td>IEC61850MMS Ethernet</td>
<td>初期通信においてデータ型を取得するGetVariableAccessAttributesに対してエラー応答が返ってきた場合、初期通信をやり直さずに次の通信に移行するよう仕様変更</td>
</tr>
<tr>
<td>1270324</td>
<td>IEC61850MMS Ethernet</td>
<td>初期通信の際にGetVariableAccessAttributesでデータ型を取得するアイテムのトップの階層を指定できるように仕様変更</td>
</tr>
<tr>
<td>1270325</td>
<td>IEC61850MMS Ethernet</td>
<td>初期通信においてRptIDおよびDatSetの値を空文字で取得した際に初期通信をやり直さずに次の通信に移行するように仕様変更</td>
</tr>
<tr>
<td>1270326</td>
<td>MODBUS Ethernet</td>
<td>ユニットIDの範囲を1255から0255の範囲まで指定できるように拡張</td>
</tr>
<tr>
<td>1270327</td>
<td>SAIA Ethernet</td>
<td>デバイス種別I、O、Fにおいて配列の要素数とタグ設定のサイズが一致するように仕様変更</td>
</tr>
</table>
</blockquote>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 不具合修正</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目</td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270331</td>
<td>全種</td>
<td>スタートアッププロジェクトに指定された設定ファイルにHTTPクライアントまたはMQTTクライアントがある場合、設定ツール起動時に設定ツールからランタイムへ設定を書き込むと設定を変更していなくてもファイルを閉じる際に設定保存確認のポップアップが表示される現象を改善</td>
</tr>
<tr>
<td>1270341</td>
<td>OPC UAサーバー</td>
<td>OPC UAのMonitoredItemsに関する診断リストでコメント列にステータス状態が表示される現象を改善</td>
</tr>
<tr>
<td>1270342</td>
<td>MQTTクライアント</td>
<td>MQTTグループ設定のPublish設定を無効にするとSubscribe設定が有効であってもMQTTで受信したメッセージがタグに書き込まれない現象を改善</td>
</tr>
<tr>
<td>1270351</td>
<td>BACnet Ethernet</td>
<td>インポートしたタグの情報がランタイムに反映されない現象を改善</td>
</tr>
<tr>
<td>1270352</td>
<td>IEC60870 Ethernet</td>
<td>アイテム種別を「M_EP_TE」または「M_EP_TF」で値種別を「Value」または「Quality」に指定すると正しく値が取得できない現象を改善</td>
</tr>
<tr>
<td>1270353</td>
<td>IEC60870 Ethernet</td>
<td>値種別をTimestampにした際に、サーバーから送られてくるパケットでTIME Invalidフラグが有効なだと異常値を取得してしまう現象を改善</td>
</tr>
<tr>
<td>1270354</td>
<td>IEC61850MMS Ethernet</td>
<td>初期通信の際にデータ型を取得するGetVariableAccessAttributesに対してエラー応答が返ってきた場合でもタイムアウトエラーと判定してしまう現象を改善</td>
</tr>
<tr>
<td>1270355</td>
<td>IEC61850MMS Ethernet</td>
<td>初期通信に失敗した際の通信終了コマンドの送信漏れを改善</td>
</tr>
<tr>
<td>1270356</td>
<td>IEC61850MMS Ethernet</td>
<td>デバイス設定の通信情報の削除を実行しても通信情報が削除されない現象を改善(対象バージョン7.0.07.1.1)</td>
</tr>
<tr>
<td>1270357</td>
<td>LSIS Ethernet</td>
<td>デバイス種類をAWまたはWWを指定すると任意のデバイス番号を設定できない現象を改善</td>
</tr>
<tr>
<td>1270358</td>
<td>Melsec Serial</td>
<td>デバイス設定の「サムチェックあり」または「形式4」を有効時にPLCから2バイト以下のデータを受信するとUpdateExceptionが発生し、読み出しが正常に行われない現象を改善</td>
</tr>
<tr>
<td>1270359</td>
<td>ModbusTCPサーバー</td>
<td>ポート設定を削除してもポートがクローズされない現象を改善対象バージョン7.0.07.1.1</td>
</tr>
<tr>
<td>1270360</td>
<td>住友重機械工業 Ethernet</td>
<td>プロジェクトウィザードからデバイスを生成した際にデフォルトタグが作成されない現象を改善</td>
</tr>
</table>
</blockquote>
<div align="right"><a href="#_top" target="_self"><font size="2">先頭に戻る</font></a></div>
<!---------------------------------------------------------------------------------------------------------------------------------------------->
<hr>
<a name="Release7.1.1"></a>
<h3>- Ver 7.1.1 - 2023年8月</h3>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 不具合修正</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目</td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270201</td>
<td>全種</td>
<td>スケール変換を有効にしていないタグでも値書き込み時に一時的にスケール変換された値がキャッシュ値に反映される現象を改善対象バージョン7.1.0</td>
</tr>
<tr>
<td>1270202</td>
<td>全種</td>
<td>共通プロパティの自動ログインユーザーに編集権限のないユーザーを指定すると、ランタイムが再起動後に設定変更が出来なくなる現象を改善対象バージョン7.0.0-7.1.0</td>
</tr>
<tr>
<td>1270203</td>
<td>全種</td>
<td>スクリプト動作中に設定ツールからランタイムへ接続時に設定の書き込みを行なうとランタイムが動作を停止する現象を改善対象バージョン7.0.0-7.1.0</td>
</tr>
<tr>
<td>1270204</td>
<td>全種</td>
<td>スクリプトのJSONパースの際に対象のJSON文字列に日本語が含まれるとスクリプトエラーになる現象を改善</td>
</tr>
<tr>
<td>1270205</td>
<td>全種</td>
<td>PCのシャットダウンを妨げる現象を改善対象バージョン7.0.0-7.1.0</td>
</tr>
<tr>
<td>1270206</td>
<td>全種</td>
<td>接続テストで結果が表示されない現象を改善対象バージョン7.0.0-7.1.0</td>
</tr>
<tr>
<td>1270207</td>
<td>全種</td>
<td>設定ツールからランタイムを再起動したタイミングでランタイムの設定が初期化される現象を改善対象バージョン7.1.0</td>
</tr>
<tr>
<td>1270211</td>
<td>OPC UAサーバー</td>
<td>リフレクトポークの設定がOPC UA通信に反映されない現象を改善</td>
</tr>
<tr>
<td>1270221</td>
<td>MQTTクライアント</td>
<td>MQTTベース設定を変更した際に配下のMQTTグループ設定のサブスクライブが停止する現象を改善(対象バージョン7.1.0.1)</td>
</tr>
<tr>
<td>1270231</td>
<td>TOYOPUC Ethernet</td>
<td>ワードレジスタに対してデータ型をBOOLで配列を有効にした場合、デバイス番号を16の倍数にしないと丸められてしまう現象を改善</td>
</tr>
<tr>
<td>1270241</td>
<td>FANUC Ethernet</td>
<td>デバイス種別がアラーム詳細の時にデータ型を文字列型以外で設定しても文字列型として保存されてしまう現象を改善(対象バージョン7.1.0)</td>
</tr>
<tr>
<td>1270251</td>
<td>BACnet Ethernet</td>
<td>インポート対象のファイルにオブジェクトネームが同じでインスタンスNoが異なるデータが記述されていても同じオブジェクトネームのタグは1タグしか生成されない現象を改善</td>
</tr>
</table>
</blockquote>
<div align="right"><a href="#_top" target="_self"><font size="2">先頭に戻る</font></a></div>
<!---------------------------------------------------------------------------------------------------------------------------------------------->
<hr>
<a name="Release7.1.0"></a>
<h3>- Ver 7.1.0 - 2023年5月</h3>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 新機能</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目            </td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270101</td>
<td>MQTTクライアント</td>
<td>MQTTクライアント機能においてMQTTで受信したメッセージをタグに書込みを行えるサブスクライブ機能に対応</td>
</tr>
<tr>
<td>1270102</td>
<td>EARLYOBSERVER</td>
<td>JCC製AEセンサEarly Observer MEL-E Unoに対応</td>
</tr>
<tr>
<td>1270103</td>
<td>SBUS Etherrnet</td>
<td>SAIA製PLC PCDシリーズに対応</td>
</tr>
<tr>
<td>1270104</td>
<td>HIDIC Ethernet</td>
<td>日立製作所製PLC S10シリーズに対応</td>
</tr>
<tr>
<td>1270105</td>
<td>MODBUS Ethernet</td>
<td>三菱電機エンジニアリング製 SineWave形AEセンサに対応</td>
</tr>
<tr>
<td>1270106</td>
<td>MODBUS Ethernet</td>
<td>オムロン製 アドバンスド・モータ状態監視機器 K7DDに対応</td>
</tr>
<tr>
<td>1270107</td>
<td>YASKAWA ROBOT</td>
<td>64ビット版アプリケーションにおいて安川電機ロボットシミュレータに対応</td>
</tr>
</table>
</blockquote>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 仕様改善</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目            </td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270111</td>
<td>全種</td>
<td>設定ツールだけでなくランタイムにおいてもスタートアップファイルで指定されたプロジェクトファイル(.dxp)を起動する仕様に変更</td>
</tr>
<tr>
<td>1270112</td>
<td>全種</td>
<td>ツールバーからランタイムへの設定の読出しと書込みを行える仕様に変更</td>
</tr>
<tr>
<td>1270113</td>
<td>全種</td>
<td>KEPServerEXの設定ファイルからタグ設定をインポートする際にグループ設定を作成する機能に対応</td>
</tr>
<tr>
<td>1270114</td>
<td>全種</td>
<td>スクリプトにJSONパーサークラスを追加</td>
</tr>
<tr>
<td>1270121</td>
<td>OPC UAサーバー</td>
<td>OPC UAサーバー機能において通信の最大セッション数を50から100に拡張</td>
</tr>
<tr>
<td>1270122</td>
<td>OPC UAサーバー</td>
<td>OPC UA Alarm&Conditionでの通信においてEventNotifierを持つオブジェクトが監視対象に追加された際に、そのオブジェクトが発報するイベントのソースタグでデータソースとの通信が発生するように仕様変更</td>
</tr>
<tr>
<td>1270123</td>
<td>HTTPクライアント<br/>
MQTTクライアント</td>
<td>HTTPクライアント及びMQTTクライアント機能において送信メッセージに埋め込み可能な時刻フォーマットを編集できるように仕様変更</td>
</tr>
<tr>
<td>1270124</td>
<td>HTTPクライアント</td>
<td>HTTPクライアント機能において証明書を指定せずにTLS通信ができるように仕様変更</td>
</tr>
<tr>
<td>1270125</td>
<td>ヒストリカルデータ</td>
<td>ヒストリカルデータ機能において定周期でタグをロギングする機能に対応</td>
</tr>
<tr>
<td>1270131</td>
<td>MELSEC EZSocket</td>
<td>ワードレジスタへのビット位置指定書き込みに対応</td>
</tr>
<tr>
<td>1270132</td>
<td>MODBUS Ethernet</td>
<td>ワードレジスタへのビット/バイト位置指定書き込みに対応</td>
</tr>
<tr>
<td>1270133</td>
<td>FANUC Focas</td>
<td>メインプログラム番号/アラーム情報の取得機能に対応</td>
</tr>
<tr>
<td>1270134</td>
<td>BACnet Ethernet</td>
<td>BAS標準インターフェースで仕様(IEIEJ/p-0003-2000)のオブジェクトリスト授受用CSVファイルフォーマット準拠のCSVファイルからのタグの自動生成機能に対応</td>
</tr>
<tr>
<td>1270135</td>
<td>YASKAWA ROBOT</td>
<td>設定可能なコントローラ番号の範囲を拡張0-255</td>
</tr>
<tr>
<td>1270136</td>
<td>IEC61850 Ethernet</td>
<td>CIDファイルからのタグインポート時にDataSet単位でグループを生成する機能に対応</td>
</tr>
<tr>
<td>1270137</td>
<td>IEC61850 Ethernet</td>
<td>Control(CO)への書き込みに失敗したときに、返されることがある非同期メッセージに含まれるエラー情報をシステムタグで取得するよう対応</td>
</tr>
<tr>
<td>1270138</td>
<td>DNP3 Ethernet</td>
<td>タグのPlayback値の更新タイミングを周期で指定するように仕様変更</td>
</tr>
</table>
</blockquote>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 不具合修正</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目</td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270141</td>
<td>全種</td>
<td>OPC UA サーバー/クライアント/HTTPクライアント/MQTTクライアント機能で利用しているOpenSSLのライブラリのバージョンを1.1.1nから1.1.1tへ更新<br/>
以下の脆弱正を改善<br/>
-メモリの内容を読み取られる<br/>
-システムがサービス運用妨害DoS状態にされる<br/>
-ソフトウェアが送信したアプリケーションのデータを復号される<br/>
原因OpenSSLに起因する脆弱性<br/>
脆弱性:<br/>
CVE-2023-0286(CVSSスコア:CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H 基本値: 7.4)<br/>
-攻撃により、メモリ内容を読み取ったり、サービス妨害を実行したりできる可能性があります。<br/>
詳細は<a href="https://nvd.nist.gov/vuln/detail/CVE-2023-0286">https://nvd.nist.gov/vuln/detail/CVE-2023-0286</a>をご確認ください。<br/>
脆弱性:<br/>
CVE-2022-4304 (CVSSスコア:CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N 基本値: 5.9)<br/>
-攻撃により、ソフトウェアが送信したアプリケーションのデータを復号される可能性があります。<br/>
詳細は<a href="https://nvd.nist.gov/vuln/detail/CVE-2022-4304">https://nvd.nist.gov/vuln/detail/CVE-2022-4304</a>をご覧ください。<br/>
脆弱性:<br/>
CVE-2023-0215 (CVSSスコア:CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 基本値: 7.5)<br/>
-攻撃により、サービス運用妨害DoS状態にされる可能性があります。<br/>
詳細は<a href="https://nvd.nist.gov/vuln/detail/CVE-2023-0215">https://nvd.nist.gov/vuln/detail/CVE-2023-0215</a>をご覧ください。<br/>
脆弱性:<br/>
CVE-2022-4450 (CVSSスコア:CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 基本値: 7.5)<br/>
-攻撃により、サービス運用妨害DoS状態にされる可能性があります。<br/>
詳細は<a href="https://nvd.nist.gov/vuln/detail/CVE-2022-4450">https://nvd.nist.gov/vuln/detail/CVE-2022-4450</a>をご覧ください。<br/>
対象:デバイスエクスプローラ OPCサーバー Ver.6.0-6.7、7.0<br/>
対策:Ver.6.8.0.1またはVer.7.1.0.1へアップデートする。</td>
</tr>
<tr>
<td>1270142</td>
<td>全種</td>
<td>ログをCSV形式で正しく出力できない現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270143</td>
<td>全種</td>
<td>表示言語を切り替えるとメッセージビューが更新されなくなる現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270144</td>
<td>全種</td>
<td>ブリッジ設定において全てのブリッジのペアを削除しても、以前に設定したタグのペアでブリッジが継続される現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270145</td>
<td>全種</td>
<td>メソッドタグが存在する構造体テンプレートをデータソース配下のデバイスまたはグループで構造体タグとして作成した際に、構造体タグの設定変更ができなくなる現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270146</td>
<td>全種</td>
<td>プロジェクトエクスプローラからポート設定を削除してもポート設定が残り続ける現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270147</td>
<td>全種</td>
<td>構造体タグが存在する場合にタグリストの画面描画に時間がかかる現象を改善</td>
</tr>
<tr>
<td>1270148</td>
<td>全種</td>
<td>スクリプト内で定義したLuaの関数を呼すと、関数内で参照しているタグの通信が止まる現象を改善</td>
</tr>
<tr>
<td>1270149</td>
<td>全種</td>
<td>値書き込み時にOPC UA A&C及びOPC AEで想定外のアラーム発報が発生する現象を改善</td>
</tr>
<tr>
<td>1270151</td>
<td>OPC DAサーバー</td>
<td>OPC DAクライアントからのDisconnectまたはRemoveItemによりアプリケーションが動作を停止する現象を改善</td>
</tr>
<tr>
<td>1270152</td>
<td>OPC UAサーバー</td>
<td>英語OSでOPC UAサーバー設定画面が見切れてしまう現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270153</td>
<td>OPC UAサーバー</td>
<td>OPC UAサーバー機能において、クライアントから32bit符号なし整数の最大数(4294967295)のタグの履歴点数に対してHistoryReadされると1点も読み出しが行われない現象を改善</td>
</tr>
<tr>
<td>1270154</td>
<td>HTTPクライアント<br/>
MQTTクライアント</td>
<td>HTTP/MQTTクライアントグループ設定の送信メッセージフォーマット編集の送信メッセージで用意されたマクロ以外の文字列を<>で囲うと、送信時にその文字列が空となる現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270161</td>
<td>AB Ethernet</td>
<td>ファームウェアバージョンVer34以降のAB Logixと接続できない現象を改善</td>
</tr>
<tr>
<td>1270162</td>
<td>AB Ethernet<br/>
SYSMAC EtherNet/IP<br/>
SYSMAC CX-Compolet<br/>
EtherNet/IP</td>
<td>設定ツールからダイナミックタグでアクセスする際に正常に値が表示されない現象を改善</td>
</tr>
<tr>
<td>1270163</td>
<td>BACnet Ethernet</td>
<td>非対応のパケット(Who-Isコマンドなど)を受信後に通信異常が発生し、以降復旧しない現象を改善</td>
</tr>
<tr>
<td>1270164</td>
<td>BACnet Ethernet</td>
<td>BinaryOutputオブジェクトのPresent Valueプロパティへの書き込みに失敗する現象を改善</td>
</tr>
<tr>
<td>1270165</td>
<td>FANUC Focas</td>
<td>機器との通信状態に関わらず接続テストに失敗してしまう現象を改善</td>
</tr>
<tr>
<td>1270166</td>
<td>IEC60870-5-104 Ethernet</td>
<td>機器に対して書込みを行った際に機器には書き込まれるが、書き込み結果がタグに反映されない現象を改善</td>
</tr>
<tr>
<td>1270167</td>
<td>MEMOBUS Serial(RTU)</td>
<td>5バイト以上で分割された応答パケットを受信すると、正常な応答パケットでも通信異常となる現象を改善</td>
</tr>
<tr>
<td>1270168</td>
<td>MODBUS Serial(RTU)<br/>
MEMOBUS Serial(RTU)</td>
<td>応答パケットに含まれるCRC値が異常でも通信に成功し、タグに値が反映されてしまう現象を改善</td>
</tr>
<tr>
<td>1270169</td>
<td>MTConnect</td>
<td>画面操作によるグループ作成がランタイム側で反映されない現象を改善対象バージョン7.0.0-7.0.1</td>
</tr>
<tr>
<td>1270170</td>
<td>OPC UA クライアント</td>
<td>日本語が含まれるードが存在するOPC UAサーバーに対してブラウズを行うと設定ツールが動作しなくなる現象を改善</td>
</tr>
<tr>
<td>1270171</td>
<td>SYSMAC FinsGateway</td>
<td>PLCとの通信でタイムアウトエラーが発生しても、通信のリトライが行なわれない現象を改善</td>
</tr>
</table>
</blockquote>
<div align="right"><a href="#_top" target="_self"><font size="2">先頭に戻る</font></a></div>
<!---------------------------------------------------------------------------------------------------------------------------------------------->
<hr>
<a name="Release7.0.1"></a>
<h3>- Ver 7.0.1 - 2023年2月</h3>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 不具合修正</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目            </td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270001</td>
<td>全種</td>
<td>サービス起動時にOPC DAクライアントと接続できない現象を改善対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270002</td>
<td>全種</td>
<td>ログ設定のファイル保存パスに存在しないフォルダを指定するとアプリケーションが動作を停止する現象を改善対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270003</td>
<td>全種</td>
<td>OPC DAクライアントからの接続で同じタグ数のグループが複数存在すると、診断ビューのOPC DAグループの診断リストに選択していないグループのタグが表示される現象を改善対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270004</td>
<td>全種</td>
<td>イベントスクリプトを設定するとCPU負荷が上昇する現象を改善対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270005</td>
<td>全種</td>
<td>ユーザー設定項目でAdministratorユーザーのOPC UA認証設定を変更できない現象を改善対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270006</td>
<td>全種</td>
<td>設定ツールがランタイムと接続中に新規にプロジェクトを開くとランタイムと切断して前回の設定でランタイムが稼働し続ける現象を改善 対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270011</td>
<td>AB</td>
<td>OPC UAクライアントから文字列配列タグへ書き込みするとアプリケーションが動作を停止する現象を改善対象バージョン7.0.0</td>
</tr>
<tr>
<td>1270021</td>
<td>Modbus/TCP Server</td>
<td>設定ツールを起動中にModbus TCPサーバー機能が正しく動作しない場合がある現象を改善対象バージョン7.0.0</td>
</tr>
</table>
</blockquote>
<div align="right"><a href="#_top" target="_self"><font size="2">先頭に戻る</font></a></div>
<!---------------------------------------------------------------------------------------------------------------------------------------------->
<hr>
<a name="Release7.0.0"></a>
<h3>- Ver 7.0.0 - 2022年11月</h3>
<table border="0" cellpadding="0" cellspacing="0" width="300" style="border-collapse: collapse" bordercolor="#111111">
<tr>
<td bgcolor="#4169E1" width="8"> </td>
<td><font size="4"> 新機能</font></td>
</tr>
</table>
<blockquote>
<table class="ReleaseNote">
<tr class="Header">
<td width="100" nowrap>リリース番号 </td>
<td width="180" nowrap>項目            </td>
<td width="100%" >内容</td>
</tr>
<tr>
<td>1270000</td>
<td>全種</td>
<td>新バージョンリリース</td>
</tr>
</table>
</blockquote>
<div align="right"><a href="#_top" target="_self"><font size="2">先頭に戻る</font></a></div>
<!------------------------------------------------------------------------------------------------------------------------------------->
<hr>
</blockquote>
<br>
<div align="right"><a href="#_top" target="_self">先頭に戻る</a></div>
<hr>
<!-- Footer -->
<br>
<br>
<table width="100%" border="0" cellpadding="0" cellspacing="0">
<tr>
<td width="100%" height="22" bgcolor="#C8DDFF" align="right"><font size="2">Copyright &copy; 1998-2023 TAKEBISHI Corporation All rights reserved.</font></td>
</tr>
</table>
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tr>
<td width="50%">
<a href="https://www.takebishi.co.jp/">株式会社たけびし</a><br>
〒615-8501 京都市右京区西京極豆田町29
</td>
<td width="50%" align="right">
<a href="https://www.faweb.net/" target=_blank>FAWEB</a><br>
</td>
</tr>
</table>
</body>
</html>